Water & Admixture System Parts
Water pumps, flow meters, water valves, admixture pumps, admixture weighing systems, piping and fittings.
Water & Admixture Parts for Concrete Batching Plants
Quality replacement parts with factory-direct pricing. Contact us for a complete list.
Available Water & Admixture Parts
| Part Name | Common Material | Specifications |
|---|---|---|
| Water Pumps | Centrifugal, self-priming | For batching water systems |
| Flow Meters | Electromagnetic / turbine | DN25 – DN100 |
| Water Valves | Pneumatic butterfly | DN50 – DN150 |
| Admixture Pumps | Corrosion resistant | For liquid admixtures |
| Admixture Tanks | PP / stainless steel | 100 – 500 L |
How to Order the Right Parts
To ensure the correct fit, please provide us with:
- Your mixer / plant model (e.g. HZS120, JS2000)
- The part name and quantity needed
- Photos or drawings of the worn part (if available)
- Your plant's serial number or year of manufacture
Need a quote? Send us your plant model and part list — we respond within 4 hours with specifications, material options and factory pricing. WhatsApp: +86 187 6888 8850
Water & Admixture Parts FAQ
What water pump do I need for HZS60?
An HZS60 typically uses a 2.2-3 kW centrifugal pump. Send us your plant model and required flow rate for a precise match.
Do you supply flow meters for admixture dosing?
Yes, we supply electromagnetic and turbine flow meters with digital readouts for accurate admixture dosing.
Can you supply complete water metering systems?
Yes, including pump, flow meter, valves and PLC integration for automatic water dosing.
How often should the admixture dosing pump be calibrated?
After every delivery of a different batch or brand, and monthly at minimum. In hot climates re-check whenever daytime temperature shifts by more than about 10 degrees, because viscosity change moves the delivered volume.
Why does the admixture dose drift over a shift?
Either the peristaltic hose is creeping as it warms and softens, or the flow meter is scaling up. Compare a weighed test batch at the start and end of a shift — if the panel reading holds but the physical volume falls, the hose is going.
What happens if admixture crystallises in the line?
The pump pressure rises, the dose falls to zero, and on some pumps the diaphragm or hose fails. Flush the line with clean water and check the strainer and check valve. Do not try to clear crystallised accelerator by running the pump hard against a blockage.
Can I dose two admixtures with one pump?
Not safely. Plasticisers and accelerators react with each other, and a blended line will block or dose the wrong ratio. Use one pump and one line per product, and inject them at separate points into the mixer.
Dosing errors that are not the pump's fault
When a mix starts coming out short of set time or with visible variation between loads, the dosing pump gets replaced first and blamed second. In practice the pump is often holding its stroke accurately while the measurement around it has moved. Check the measurement before you buy hardware.
The most common trap is calibration drift that nobody re-checks. A pump calibrated in cool weather with a thin admixture will over-dose once the same product arrives warm and thicker, or once a fresh delivery changes viscosity. Where a flow meter is fitted, scaling on the meter internals does the opposite — it under-reads, the pump runs longer, and consumption climbs without any change to the batch record. Weigh a test batch and compare what actually went into the mixer against what the panel says. That single check separates a pump problem from a metering problem.
The second trap is the line, not the pump. Peristaltic hose creeps as it ages: the wall thins, the roller squeezes less, and output falls gradually enough that nobody notices for weeks. Diaphragm pumps lose output when the diaphragm stiffens or the check valve seats get grit under them. Both look like a failed pump and both are a service kit.
Dose is off — where to look
| What you see | Likely cause | Check |
|---|---|---|
| Dose drifts down over a shift | Peristaltic hose creep, worn roller | Delivered volume against a timed test |
| Dose high only in hot weather | Admixture viscosity dropped | Re-calibrate with the product as delivered |
| Meter and scale disagree | Scaling on flow meter internals | Weigh a batch, compare to panel record |
| Pump runs but nothing moves | Air lock or crystallised line | Suction strainer and line flush |
| Dose fluctuates load to load | Check valve grit or failing diaphragm | Service kit, not a new pump |
| Consumption climbing, mix fine | Under-reading flow meter | Meter calibration certificate age |
Cleaning beats any part you can buy
Set accelerators and some retarders crystallise in the line if they sit. A line left full overnight can be blocked by morning, and the blockage is usually in the narrowest place — a check valve, a strainer, or a metering orifice. Flush with clean water at the end of every shift if the product is a set accelerator, and do not assume a short shutdown is safe.
Where two admixtures are dosed, keep them on separate pumps and separate lines. Sharing a line between a plasticiser and an accelerator is a recipe for reaction in the pipe and a very confusing fault to chase. If the plant layout only allows one line, dose them at different points and never let the lines join before the mixer.